EHSXB04P30DA3 / ERGA04EAV3A |
EHSXB04P50DA3 / ERGA04EAV3A |
EHSXB08P30DA3 / ERGA06EAV3A |
EHSXB08P50DA3 / ERGA06EAV3A |
EHSXB08P30DA3 / ERGA08EAV3A |
EHSXB08P50DA3 / ERGA08EAV3A |
Indoor unit
|
EHSXB04P30DA3
|
EHSXB04P50DA3
|
EHSXB08P30DA3
|
EHSXB08P50DA3
|
EHSXB08P30DA3
|
EHSXB08P50DA3
|
Heating capacity
|
Nom.
|
kW
|
4.30, 4.60
|
4.30, 4.60
|
6.00, 5.90
|
6.00, 5.90
|
7.50, 7.80
|
7.50, 7.80
|
Cooling capacity
|
Nom.
|
kW
|
4.86, 4.52
|
4.86, 4.52
|
5.96, 5.09
|
5.96, 5.09
|
6.25, 5.44
|
6.25, 5.44
|
Power input
|
Heating
|
Nom.
|
kW
|
0.840, 1.26
|
0.840, 1.26
|
1.24, 1.69
|
1.24, 1.69
|
1.63, 2.23
|
1.63, 2.23
|
|
Cooling
|
Nom.
|
kW
|
0.810, 1.36
|
0.810, 1.36
|
1.06, 1.55
|
1.06, 1.55
|
1.16, 1.73
|
1.16, 1.73
|
COP
|
5.10, 3.65
|
5.10, 3.65
|
4.85, 3.50
|
4.85, 3.50
|
4.60, 3.50
|
4.60, 3.50
|
EER
|
5.98, 3.32
|
5.98, 3.32
|
5.61, 3.28
|
5.61, 3.28
|
5.40, 3.14
|
5.40, 3.14
|
Domestic hot water heating
|
General
|
Declared load profile
|
|
L
|
XL
|
L
|
XL
|
L
|
XL
|
|
Average climate
|
Water heating energy efficiency class
|
|
A+
|
A
|
A+
|
A
|
A+
|
A
|
Space heating
|
Average climate water outlet 55°C
|
General
|
SCOP
|
|
3.29
|
3.29
|
3.27
|
3.27
|
3.30
|
3.30
|
|
|
|
Seasonal space heating eff. class
|
|
A++
|
A++
|
A++
|
A++
|
A++
|
A++
|
|
Average climate water outlet 35°C
|
General
|
SCOP
|
|
4.54
|
4.54
|
4.52
|
4.52
|
4.61
|
4.61
|
|
|
|
Seasonal space heating eff. class
|
|
A+++
|
A+++
|
A+++
|
A+++
|
A+++
|
A+++
|
Notes
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|