| EKVDX32A2VEB | EKVDX50A2VEB | EKVDX80A2VEB | EKVDX100A2VEB | ||||
|---|---|---|---|---|---|---|---|
| Operation range | Around unit | °CDB | 10°C~40°CDB, 80% RH or less | 10°C~40°CDB, 80% RH or less | 10°C~40°CDB, 80% RH or less | 10°C~40°CDB, 80% RH or less | |
| Weight | Unit | kg | 19.0 | 23.4 | 30.1 | 37.7 | |
| Refrigerant | Control | Motor operated expansion valve | Motor operated expansion valve | Motor operated expansion valve | Motor operated expansion valve | ||
| GWP | 675.0, 2,087.5 | 675.0, 2,087.5 | 675.0, 2,087.5 | 675.0, 2,087.5 | |||
| Type | R32/R410A | R32/R410A | R32/R410A | R32/R410A | |||
| Piping connections | Liquid | OD | mm | 6.35 | 6.35 | 6.35 | 6.35 |
| Type | Flare connection | Flare connection | Flare connection | Flare connection | |||
| Gas | OD | mm | 12.7 | 12.7 | 12.7 | 12.7 | |
| Type | Flare connection | Flare connection | Flare connection | Flare connection | |||
| Drain | VP20 (I.D. 20/O.D. 26), drain height 625 mm | VP20 (I.D. 20/O.D. 26), drain height 625 mm | VP20 (I.D. 20/O.D. 26), drain height 625 mm | VP20 (I.D. 20/O.D. 26), drain height 625 mm | |||
| Dimensions | Unit | Width | mm | 550 | 700 | 1,000 | 1,400 |
| Depth | mm | 809 | 809 | 809 | 809 | ||
| Height | mm | 250 | 250 | 250 | 250 | ||
| Casing | Material | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | ||
| Power supply | Phase | 1~ | 1~ | 1~ | 1~ | ||
| Name | VE | VE | VE | VE | |||
| Frequency | Hz | 50/60 | 50/60 | 50/60 | 50/60 | ||
| Voltage | V | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | ||
| Notes | (1) - Contains fluorinated greenhouse gases | (1) - Contains fluorinated greenhouse gases | (1) - Contains fluorinated greenhouse gases | (1) - Contains fluorinated greenhouse gases | |||
| (2) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (2) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (2) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (2) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | ||||
| (3) - Maximum allowable voltage range variation between phases is 2%. | (3) - Maximum allowable voltage range variation between phases is 2%. | (3) - Maximum allowable voltage range variation between phases is 2%. | (3) - Maximum allowable voltage range variation between phases is 2%. | ||||
| (4) - MCA represents maximum input current. | (4) - MCA represents maximum input current. | (4) - MCA represents maximum input current. | (4) - MCA represents maximum input current. | ||||
| (5) - Select wire size based on the value of MCA | (5) - Select wire size based on the value of MCA | (5) - Select wire size based on the value of MCA | (5) - Select wire size based on the value of MCA | ||||