Specifications Table for EPGA011-016DV

EPGA11DAV3 EPGA14DAV3 EPGA16DAV3
Sound pressure level Heating Nom. dBA 48.0 (2) 49.0 (2) 52.0 (2)
  Cooling Nom. dBA 55.0 (3) 55.0 (3) 55.0 (3)
Sound power level Heating Nom. dBA 64.0 (1) 64.0 (1) 66.0 (1)
  Cooling Nom. dBA 68.0 (1) 68.0 (1) 68.0 (1)
Refrigerant GWP   675.0 675.0 675.0
  Charge kg 3.50 3.50 3.50
  Type   R-32 R-32 R-32
Dimensions Unit Width mm 1,160 1,160 1,160
    Depth mm 380 380 380
    Height mm 1,440 1,440 1,440
Weight Unit kg 143 143 143
Operation range Cooling Max. °CDB 43 43 43
    Min. °CDB 10 10 10
  Domestic hot water Min. °CDB -28 -28 -28
    Max. °CDB 35 35 35
Piping connections Level difference IU - OU Max. m 10.0 10.0 10.0
Power supply Phase   1N~ 1N~ 1N~
  Name   V3 V3 V3
  Frequency Hz 50 50 50
  Voltage V 230 230 230
Current Recommended fuses A 32 32 32
Notes (1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 3 (2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 3 (2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 3
  (3) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = (3) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = (3) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT =