Specifications Table for EPGA011-016DV7

EPGA11DAV37 EPGA14DAV37 EPGA16DAV37
Sound pressure level Heating Nom. dBA 48.0 (2) 49.0 (2)
  Cooling Nom. dBA 55.0 (3) 55.0 (3)
Sound power level Heating Nom. dBA 64.0 (1) 64.0 (1)
  Cooling Nom. dBA 68.0 (1) 68.0 (1)
Refrigerant GWP   675.0 675.0
  Charge kg 3.50 3.50
  Type   R-32 R-32
Dimensions Unit Width mm 1,160 1,160
    Depth mm 380 380
    Height mm 1,440 1,440
Weight Unit kg 143 143
Operation range Cooling Max. °CDB 43 43
    Min. °CDB 10 10
  Domestic hot water Min. °CDB -28 -28
    Max. °CDB 35 35
Piping connections Level difference IU - OU Max. m 10.0 10.0
Power supply Phase   1N~ 1N~
  Name   V3 V3
  Frequency Hz 50 50
  Voltage V 230 230
Current Recommended fuses A 32 32
Notes (1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 3 (2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 3 (2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 3
  (3) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = (3) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = (3) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT =
Dimensions Unit Height mm     1440
    Width mm     1160
    Depth mm     380
Weight Unit kg     143
Operation range Cooling Min. °CDB     10
    Max. °CDB     43
  Domestic hot water Min. °CDB     -28
    Max. °CDB     35
Sound power level Heating Nom. dBA     66
  Cooling Nom. dBA     68
Sound pressure level Heating Nom. dBA     52.0 (2)
  Cooling Nom. dBA     55
Refrigerant Type       R-32
  GWP       675
  Charge tCO2Eq     2.36
  Charge kg     3.5
Piping connections Level difference IU - OU Max. m     10.0
Power supply Name       V3
  Phase       1N~
  Frequency Hz     50
  Voltage V     230
Current Recommended fuses A     32