Specifications Table for EPRA08-12EV

EPRA08EAV3 EPRA10EAV3 EPRA12EAV3
Dimensions Unit Height mm 1003 1003 1003
    Width mm 1270 1270 1270
    Depth mm 533 533 533
Weight Unit kg 118 118 118
Fan Air flow rate Heating High m³/min 80.1 80.1 80.1
    Cooling High m³/min 80.1 80.1 80.1
Operation range Cooling Min. °CDB 10 10 10
    Max. °CDB 43 43 43
  Domestic hot water Min. °CDB -28 -28 -28
    Max. °CDB 35 35 35
Sound power level Heating Nom. dBA 54.0 54.0 54.0
  Cooling Nom. dBA 60.1 60.6 61.5
Sound pressure level Heating Nom. dBA 40.6 40.6 40.6
  Cooling Nom. dBA 47 47.4 48.5
Refrigerant Type   R-32 R-32 R-32
  GWP   675.0 675.0 675.0
  Charge tCO2Eq 2.19 2.19 2.19
  Charge kg 3.25 3.25 3.25
Piping connections Level difference IU - OU Max. m 10.0 10.0 10.0
Power supply Name   V3 V3 V3
  Phase   1~ 1~ 1~
  Frequency Hz 50 50 50
  Voltage V 230 230 230
Current Recommended fuses A 32 32 32
Notes (1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
  (3) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. (3) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. (3) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.
  (4) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = (4) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = (4) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT =