| ETVH16SU23EA6V / EPRA14DAW1 | ETVH16SU18EA6V / EPRA14DAW1 | ETVH16SU23EA6V / EPRA16DAW1 | ETVH16SU18EA6V / EPRA16DAW1 | ETVH16SU18EA6V / EPRA18DAW1 | ETVH16SU23EA6V / EPRA18DAW1 | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Domestic hot water heating | General | Declared load profile | XL | XL | L | XL | ||||
| Average climate | Water heating energy efficiency class | A | A | A | A | |||||
| COP | 4.79 (2) | 4.79 | 5.00 (2) | 5.00 | 5.00 (2) | 5.00 (2) | ||||
| Space heating | Average climate water outlet 35°C | General | ηs (Seasonal space heating efficiency) | % | 186 | 186 | 186 | 186 | ||
| Seasonal space heating eff. class | A+++ | A+++ | A+++ | A+++ | ||||||
| SCOP | 4.71 | 4.71 | 4.71 | 4.71 | ||||||
| Average climate water outlet 55°C | General | Seasonal space heating eff. class | A++ | A++ | A++ | A++ | ||||
| ηs (Seasonal space heating efficiency) | % | 140 | 140 | 140 | 140 | |||||
| SCOP | 3.57 | 3.57 | 3.57 | 3.57 | ||||||
| Heat up time from 10°C to 50°C | hr | 1h13min at 7°C ambient temperature | 1h02min at 7°C ambient temperature | 1h13min at 7°C ambient temperature | 1h02min at 7°C ambient temperature | 1h02min at 7°C ambient temperature | 1h13min at 7°C ambient temperature | |||
| Heating capacity | Nom. | kW | 5.90 (2) | 9.00 (2) | 9.00 (2) | 9.00 (2) | ||||
| Min. | kW | 3.70 (1) | 3.96 (1) | 4.40 (1) | 4.40 (1) | |||||
| Max. | kW | 9.75 (1) | 10.44 (1) | 11.60 (1) | 11.60 (1) | |||||
| Power input | Heating | Max. | kW | 2.17 (5) | 2.32 (5) | 2.58 (5) | 2.58 (5) | |||
| Min. | kW | 0.84 (5) | 0.90 (5) | 1.00 (5) | 1.00 (5) | |||||
| Nom. | kW | 1.23 (2) | 1.80 (2) | 1.80 (2) | 1.80 (2) | |||||
| Domestic hot water from 10°C to 50°C | Nom. | kWh | 2.85 (6) | 2.85 (6) | 2.57 (6) | 2.85 (6) | ||||
| Notes | (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | ||||
| (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | |||||
| (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | |||||
| (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | (4) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. | (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | (4) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. | (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | |||||
| (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed | (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed | (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | |||||
| (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. | (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. | (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. | (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. | |||||||
| (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed | (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed | (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed | (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed | |||||||
| Heating capacity | Min. | kW | 3.70 | 3.96 | ||||||
| Nom. | kW | 5.90 | 9.00 | |||||||
| Max. | kW | 9.75 | 10.44 | |||||||
| Power input | Heating | Min. | kW | 0.84 | 0.90 | |||||
| Nom. | kW | 1.23 | 1.80 | |||||||
| Max. | kW | 2.17 | 2.32 | |||||||
| Domestic hot water from 10°C to 50°C | Nom. | kWh | 2.57 | 2.57 | ||||||
| Domestic hot water heating | General | Declared load profile | L | L | ||||||
| Average climate | Water heating energy efficiency class | A | A | |||||||
| Space heating | Average climate water outlet 55°C | General | SCOP | 3.57 | 3.57 | |||||
| Seasonal space heating eff. class | A++ | A++ | ||||||||
| Average climate water outlet 35°C | General | SCOP | 4.71 | 4.71 | ||||||
| Seasonal space heating eff. class | A+++ | A+++ | ||||||||