| EWSAH06UDA9W | |||||
|---|---|---|---|---|---|
| Refrigerant | Charge | TCO2Eq | 1.15 | ||
| GWP | 675.0 | ||||
| Charge | kg | 1.70 | |||
| Type | R-32 | ||||
| Operation range | Installation space | Min. | °C | 5 | |
| Max. | °C | 35 | |||
| Heating | Water side | Max. | °C | 65 | |
| Min. | °C | 5 | |||
| Domestic hot water | Water side | Max. | °C | 60 | |
| Min. | °C | 25 | |||
| Dimensions | Unit | Width | mm | 597 | |
| Depth | mm | 666 | |||
| Height | mm | 1,891 | |||
| Casing | Material | Precoated sheet metal | |||
| Colour | White + Black | ||||
| Tank | Water volume | l | 180 | ||
| Corrosion protection | Pickling | ||||
| Insulation | Heat loss | kWh/24h | 1.4 | ||
| Weight | Unit | kg | 222 | ||
| Space heating | Average climate water outlet 35°C | General | ηs (Seasonal space heating efficiency) | % | 252 | 
| Seasonal space heating eff. class | A+++ | ||||
| SCOP | 6.49 (1) | ||||
| Average climate water outlet 55°C | General | Seasonal space heating eff. class | A+++ | ||
| ηs (Seasonal space heating efficiency) | % | 158 | |||
| SCOP | 4.15 (1) | ||||
| Power supply | Phase | 1~/3~ | |||
| Frequency | Hz | 50 | |||
| Voltage | V | 230/400 | |||
| Current | Recommended fuses | A | 16/32 | ||
| Notes | (1) - According to EN14825 and EN14511:2018 | ||||