Specifications Table for FAA-B / RZAG-NV1

FAA71BUV1B / RZAG71N2V1B FAA71BUV1B / RZAG71N7V1B FAA100BUV1B / RZAG71N2V1B FAA100BUV1B / RZAG71N7V1B FAA100BUV1B / RZAG100N7V1B FAA71BUV1B / FAA71BUV1B / RZAG100N2V1B
Cooling capacity Nom. kW 6.80 6.80 (1)     9.50 (1)
Space cooling SEER   6.58 6.58     6.42
  Annual energy consumption kWh/a 362 362     518
  Capacity Pdesign kW 6.80 6.80     9.50
  Energy efficiency class   A++ A++     A++
Space heating (Average climate) Capacity Pdesign kW 4.70 4.70     7.80
  SCOP/A   4.20 4.20     4.01
  Energy efficiency class   A+ A+     A+
  Annual energy consumption kWh/a 1,567 1,567     2,723
Nominal efficiency EER   3.27
  Annual energy consumption kWh 1,040
  COP   3.42
  Energy labeling Directive Cooling   A
    Heating   B
Heating capacity Nom. kW 7.50 7.50 (2)     10.8 (2)
Notes   (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
    (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
Cooling capacity Nom. kW     6.80 (1) 6.80 (1)   9.50 (1)
Heating capacity Nom. kW     7.50 (2) 7.50 (2)   10.8 (2)
Space cooling Energy efficiency class       A++ A++   A+++
  Capacity Pdesign kW     6.80 6.80   9.50
  SEER       6.43 6.43   8.57
  Annual energy consumption kWh/a     370 370   388
Space heating (Average climate) Energy efficiency class       A+ A+   A++
  Capacity Pdesign kW     4.70 4.70   7.80
  SCOP/A       4.10 4.10   4.63
  Annual energy consumption kWh/a     1605 1605   2359
Energy Efficiency Range     A+++ ~ D A+++ ~ D   A+++ ~ D