FCAHG100GVEB / RZQG71L9V1B |
FCAHG71GVEB / RZQG71L9V1B |
FCAHG100GVEB / RZQG100L9V1B |
FCAHG140GVEB / RZQG100L9V1B |
FCAHG71GVEB / FCAHG71GVEB / RZQG100L9V1B |
FCAHG125GVEB / RZQG125L9V1B |
FCAHG140GVEB / RZQG125L9V1B |
FCAHG71GVEB / FCAHG71GVEB / RZQG125L9V1B |
FCAHG140GVEB / RZQG140L9V1B |
Cooling capacity
|
Nom.
|
kW
|
|
6.80 (1)
|
9.50 (1)
|
|
|
12.0 (1)
|
|
|
13.4 (1)
|
Space cooling
|
SEER
|
|
6.91
|
6.91
|
7.00
|
7.00
|
5.10
|
6.61
|
6.61
|
5.10
|
6.75
|
|
ηs,c
|
%
|
|
|
|
|
|
|
|
|
266.9
|
|
Annual energy consumption
|
kWh/a
|
345
|
345
|
475
|
475
|
652
|
636
|
636
|
824
|
1,191
|
|
Capacity
|
Pdesign
|
kW
|
6.80
|
6.80
|
9.50
|
9.50
|
9.50
|
12.0
|
12.0
|
12.0
|
13.4
|
|
Energy efficiency class
|
|
A++
|
A++
|
A++
|
A++
|
A
|
A++
|
A++
|
A
|
Space heating (Average climate)
|
Capacity
|
Pdesign
|
kW
|
7.60
|
7.60
|
11.3
|
11.30
|
11.30
|
12.7
|
12.66
|
12.71
|
11.8
|
|
SCOP/A
|
|
4.54
|
4.54
|
4.80
|
4.80
|
3.80
|
4.63
|
4.63
|
3.80
|
4.38
|
|
Energy efficiency class
|
|
A+
|
A+
|
A++
|
A++
|
A
|
A++
|
A++
|
A
|
|
Annual energy consumption
|
kWh/a
|
2,344
|
2,344
|
3,296
|
3,296
|
4,164
|
3,829
|
3,829
|
4,683
|
3,766
|
|
ηs,h
|
%
|
|
|
|
|
|
|
|
|
172.1
|
Nominal efficiency
|
EER
|
|
|
4.09 (3)
|
4.42 (3)
|
|
|
4.00 (3)
|
|
|
3.18 (3)
|
|
Annual energy consumption
|
kWh
|
|
830
|
1,075
|
|
|
1,500
|
|
COP
|
|
|
4.80 (3)
|
4.99 (3)
|
|
|
4.40 (3)
|
|
|
4.12 (3)
|
|
Energy labeling Directive
|
Cooling
|
|
|
A
|
A
|
|
|
A
|
|
|
Heating
|
|
|
A
|
A
|
|
|
A
|
Heating capacity
|
Nom.
|
kW
|
|
7.50 (2)
|
10.8 (2)
|
|
|
13.5 (2)
|
|
|
15.5 (2)
|
Notes
|
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
|
|
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
|
|
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
|
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
|
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
|
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
|
|
|
(3) - EER/COP according to Eurovent 2012, for use outside EU only
|
(3) - EER/COP according to Eurovent 2012, for use outside EU only
|
|
|
(3) - EER/COP according to Eurovent 2012, for use outside EU only
|
|
|