Specifications Table for FCAHG-G / RZQG-L9V1

FCAHG100GVEB / RZQG71L9V1B FCAHG71GVEB / RZQG71L9V1B FCAHG100GVEB / RZQG100L9V1B FCAHG140GVEB / RZQG100L9V1B FCAHG71GVEB / FCAHG71GVEB / RZQG100L9V1B FCAHG125GVEB / RZQG125L9V1B FCAHG140GVEB / RZQG125L9V1B FCAHG71GVEB / FCAHG71GVEB / RZQG125L9V1B FCAHG140GVEB / RZQG140L9V1B
Cooling capacity Nom. kW   6.80 (1) 9.50 (1)     12.0 (1)     13.4 (1)
Space cooling SEER   6.91 6.91 7.00 7.00 5.10 6.61 6.61 5.10 6.75
  ηs,c %                 266.9
  Annual energy consumption kWh/a 345 345 475 475 652 636 636 824 1,191
  Capacity Pdesign kW 6.80 6.80 9.50 9.50 9.50 12.0 12.0 12.0 13.4
  Energy efficiency class   A++ A++ A++ A++ A A++ A++ A
Space heating (Average climate) Capacity Pdesign kW 7.60 7.60 11.3 11.30 11.30 12.7 12.66 12.71 11.8
  SCOP/A   4.54 4.54 4.80 4.80 3.80 4.63 4.63 3.80 4.38
  Energy efficiency class   A+ A+ A++ A++ A A++ A++ A
  Annual energy consumption kWh/a 2,344 2,344 3,296 3,296 4,164 3,829 3,829 4,683 3,766
  ηs,h %                 172.1
Nominal efficiency EER     4.09 (3) 4.42 (3)     4.00 (3)     3.18 (3)
  Annual energy consumption kWh   830 1,075     1,500
  COP     4.80 (3) 4.99 (3)     4.40 (3)     4.12 (3)
  Energy labeling Directive Cooling     A A     A
    Heating     A A     A
Heating capacity Nom. kW   7.50 (2) 10.8 (2)     13.5 (2)     15.5 (2)
Notes   (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m     (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m     (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
    (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m     (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m     (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
    (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only     (3) - EER/COP according to Eurovent 2012, for use outside EU only     (3) - EER/COP according to Eurovent 2012, for use outside EU only