Specifications Table for FTXF-D / RXF-F

FTXF50D2V1B / RXF50F5V1B
Outdoor unit RXF50F5V1B
Cooling capacity Min. kW 1.3
  Nom. kW 5
  Max. kW 5.3
Heating capacity Min. kW 1.43
  Nom. kW 5.4
  Max. kW 6.13
Nominal efficiency EER   3.3
  COP   3.71
  Annual energy consumption kWh 269
  Energy labeling Directive Cooling   A
    Heating   A
Space cooling Energy efficiency class   A++
  Capacity Pdesign kW 5
  SEER   6.5
  Annual energy consumption kWh/a 269
Space heating (Average climate) Energy efficiency class   A+
  Capacity Pdesign kW 3.8
  SCOP/A   4.1
  Pdh Heating capacity at -10° kW 3.24
  Annual energy consumption kWh/a 1297
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series
  (3) - See separate drawing for electrical data