| FTXF20F5V1B / RXF20F5V1B | FTXF25F5V1B / RXF25F5V1B | FTXF35F5V1B / RXF35F5V1B | FTXF42F5V1B / RXF42F5V1B | FTXF50F5V1B / RXF50F5V1B | ||||
|---|---|---|---|---|---|---|---|---|
| Outdoor unit | RXF20F5V1B | RXF25F5V1B | RXF35F5V1B | RXF42F5V1B | RXF50F5V1B | |||
| Cooling capacity | Min. | kW | 1.3 | 1.30 | 1.30 | 1.4 | 1.30 | |
| Nom. | kW | 2 | 2.50 | 3.30 | 4.2 | 5 | ||
| Max. | kW | 2.4 | 2.80 | 3.80 | 4.3 | 5.30 | ||
| Heating capacity | Min. | kW | 1.3 | 1.30 | 1.30 | 1.4 | 1.43 | |
| Nom. | kW | 2.4 | 2.80 | 3.50 | 4.6 | 5.40 | ||
| Max. | kW | 3.3 | 3.70 | 4.40 | 5 | 6.13 | ||
| Nominal efficiency | EER | 3.38 | 3.24 | 3.30 | 3.3 | 3.30 | ||
| COP | 3.75 | 3.73 | 3.72 | 3.71 | 3.71 | |||
| Annual energy consumption | kWh | 108 | 135 | 188 | 226 | 269 | ||
| Energy labeling Directive | Cooling | A | A | A | A | A | ||
| Heating | A | A | A | A | A | |||
| Space cooling | Energy efficiency class | A++ | A++ | A++ | A++ | A++ | ||
| Capacity | Pdesign | kW | 2 | 2.50 | 3.50 | 4.2 | 5 | |
| SEER | 6.5 | 6.50 | 6.50 | 6.5 | 6.50 | |||
| Annual energy consumption | kWh/a | 108 | 135 | 188 | 226 | 269 | ||
| Space heating (Average climate) | Energy efficiency class | A+ | A+ | A+ | A+ | A+ | ||
| Capacity | Pdesign | kW | 2.2 | 2.40 | 2.60 | 3.3 | 3.80 | |
| SCOP/A | 4.2 | 4.20 | 4.20 | 4.3 | 4.10 | |||
| Pdh Heating capacity at -10° | kW | 1.86 | 1.97 | 2.21 | 2.61 | 3.24 | ||
| Annual energy consumption | kWh/a | 733 | 801 | 867 | 1,075 | 1,297 | ||
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | ||||
| (3) - See separate drawing for electrical data | (3) - See separate drawing for electrical data | (3) - See separate drawing for electrical data | (3) - See separate drawing for electrical data | (3) - See separate drawing for electrical data | ||||