Specifications Table for FTXM-R / 3MXM-N8

FTXM20R2V1B / FTXM20R2V1B / 3MXM40N2V1B8 FTXM20R5V1B / FTXM20R5V1B / 3MXM40N2V1B8 FTXM25R2V1B / FTXM25R2V1B / 3MXM52N2V1B8 FTXM25R5V1B / FTXM25R5V1B / 3MXM52N2V1B8
Cooling capacity Nom. kW 4.00 4.00 5.0 5.0
Nominal efficiency EER   4.76 4.76 4.85 4.85
  Annual energy consumption kWh 420 420 515 515
  COP   4.73 4.73 4.45 4.45
  Energy labeling Directive Cooling   A A A A
    Heating   A A A A
Space cooling Annual energy consumption kWh/a 165 165 204 204
  Capacity Pdesign kW 4.00 4.00 5.00 5.00
Space heating (Average climate) Capacity Pdesign kW 4.80 4.80 4.80 4.80
  Pdh Heating capacity at -10° kW 3.60 3.60
  Annual energy consumption kWh/a 1,582 1,582 1,533 1,533
Heating capacity Nom. kW 4.60 4.60 6.80 6.80
Space cooling SEER   8.52 8.52 8.59 8.59
  Energy efficiency class   A+++ A+++ A+++ A+++
Space heating (Average climate) SCOP/A   4.24 4.24 4.38 4.38
  Energy efficiency class   A+ A+ A+ A+
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data