| FTXM20R5V1B / RXM20N5V1B9 | FTXM20R2V1B / RXM20N5V1B9 | FTXM20R2V1B / RXM20N2V1B9 | FTXM20R5V1B / RXM20N2V1B9 | FTXM25R2V1B / RXM25N5V1B9 | FTXM25R5V1B / RXM25N5V1B9 | FTXM25R5V1B / RXM25N2V1B9 | FTXM25R2V1B / RXM25N2V1B9 | FTXM35R2V1B / RXM35N5V1B9 | FTXM35R5V1B / RXM35N5V1B9 | FTXM35R5V1B / RXM35N2V1B9 | FTXM35R2V1B / RXM35N2V1B9 | FTXM50R2V1B / RXM50N2V1B9 | FTXM60R2V1B / RXM60N2V1B9 | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Outdoor unit | RXM20N5V1B9 | RXM20N5V1B9 | RXM20N5V1B9 | RXM20N5V1B9 | RXM25N5V1B9 | RXM25N5V1B9 | RXM25N5V1B9 | RXM25N5V1B9 | RXM35N5V1B9 | RXM35N5V1B9 | RXM35N5V1B9 | RXM35N5V1B9 | RXM50N2V1B9 | RXM60N2V1B9 | |||
| Cooling capacity | Min. | kW | 1.30 | 1.30 | 1.30 | 1.30 | 1.30 | 1.30 | 1.30 | 1.30 | 1.40 | 1.40 | 1.70 | 1.70 | |||
| Nom. | kW | 2.00 | 2.00 | 2.00 | 2.00 | 2.50 | 2.50 | 2.50 | 2.50 | 3.40 | 3.40 | 5.00 | 6.00 | ||||
| Max. | kW | 2.60 | 2.60 | 2.60 | 2.60 | 3.20 | 3.20 | 3.20 | 3.20 | 4.00 | 4.00 | 6.00 | 7.00 | ||||
| Heating capacity | Min. | kW | 1.30 | 1.30 | 1.30 | 1.30 | 1.30 | 1.30 | 1.30 | 1.30 | 1.40 | 1.40 | 1.70 | 1.70 | |||
| Nom. | kW | 2.50 | 2.50 | 2.50 | 2.50 | 2.80 | 2.80 | 2.80 | 2.80 | 4.00 | 4.00 | 5.80 | 7.00 | ||||
| Max. | kW | 3.50 | 3.50 | 3.50 | 3.50 | 4.70 | 4.70 | 4.70 | 4.70 | 5.20 | 5.20 | 7.70 | 8.00 | ||||
| Nominal efficiency | Annual energy consumption | kWh | 219 | 219 | 219 | 219 | 278 | 278 | 278 | 278 | 402 | 402 | 679 | 885 | |||
| COP | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 4.04 | 4.04 | 4.00 | 3.61 | |||||
| EER | 4.57 | 4.57 | 4.57 | 4.57 | 4.50 | 4.50 | 4.50 | 4.50 | 4.23 | 4.23 | 3.68 | 3.39 | |||||
| Energy labeling Directive | Cooling | A | A | A | A | A | A | A | A | A | A | A | A | ||||
| Heating | A | A | A | A | A | A | A | A | A | A | A | A | |||||
| Space cooling | Annual energy consumption | kWh/a | 81 | 81 | 81 | 81 | 101 | 101 | 101 | 101 | 138 | 138 | 236 | 304 | |||
| Energy efficiency class | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A++ | A++ | |||||
| Capacity | Pdesign | kW | 2.00 | 2.00 | 2.00 | 2.00 | 2.50 | 2.50 | 2.50 | 2.50 | 3.40 | 3.40 | 5.00 | 6.00 | |||
| SEER | 8.65 | 8.65 | 8.65 | 8.65 | 8.65 | 8.65 | 8.65 | 8.65 | 8.65 | 8.65 | 7.41 | 6.90 | |||||
| Space heating (Average climate) | Annual energy consumption | kWh/a | 632 | 632 | 632 | 632 | 659 | 659 | 659 | 659 | 687 | 687 | 1,369 | 1,562 | |||
| Capacity | Pdesign | kW | 2.30 | 2.30 | 2.30 | 2.30 | 2.40 | 2.40 | 2.40 | 2.40 | 2.50 | 2.50 | 4.60 | 4.80 | |||
| Energy efficiency class | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A++ | A+ | |||||
| Pdh Heating capacity at -10° | kW | 2.24 | 2.24 | 2.24 | 2.24 | 2.30 | 2.30 | 2.30 | 2.30 | 2.35 | 2.35 | 4.09 | 4.11 | ||||
| SCOP/A | 5.10 | 5.10 | 5.10 | 5.10 | 5.10 | 5.10 | 5.10 | 5.10 | 5.10 | 5.10 | 4.71 | 4.30 | |||||
| Notes | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | |||
| (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | ||||
| (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| Cooling capacity | Min. | kW | 1.40 | 1.40 | |||||||||||||
| Nom. | kW | 3.40 | 3.40 | ||||||||||||||
| Max. | kW | 4.00 | 4.00 | ||||||||||||||
| Heating capacity | Min. | kW | 1.40 | 1.40 | |||||||||||||
| Nom. | kW | 4.00 | 4.00 | ||||||||||||||
| Max. | kW | 5.20 | 5.20 | ||||||||||||||
| Nominal efficiency | EER | 4.23 | 4.23 | ||||||||||||||
| COP | 4.04 | 4.04 | |||||||||||||||
| Annual energy consumption | kWh | 402 | 402 | ||||||||||||||
| Energy labeling Directive | Cooling | A | A | ||||||||||||||
| Heating | A | A | |||||||||||||||
| Space cooling | Energy efficiency class | A+++ | A+++ | ||||||||||||||
| Capacity | Pdesign | kW | 3.40 | 3.40 | |||||||||||||
| SEER | 8.65 | 8.65 | |||||||||||||||
| Annual energy consumption | kWh/a | 138 | 138 | ||||||||||||||
| Space heating (Average climate) | Energy efficiency class | A+++ | A+++ | ||||||||||||||
| Capacity | Pdesign | kW | 2.50 | 2.50 | |||||||||||||
| SCOP/A | 5.10 | 5.10 | |||||||||||||||
| Pdh Heating capacity at -10° | kW | 2.35 | 2.35 | ||||||||||||||
| Annual energy consumption | kWh/a | 687 | 687 | ||||||||||||||
| Energy Efficiency Range | A+++ ~ D | A+++ ~ D | |||||||||||||||