FXKA20AMVEB |
FXKA25AMVEB |
FXKA32AMVEB |
FXKA40AMVEB |
FXKA50AMVEB |
FXKA63AMVEB |
Cooling capacity
|
Total capacity
|
At high fan speed
|
kW
|
2.2
|
2.8
|
3.6
|
4.5
|
5.6
|
7.1
|
Heating capacity
|
Total capacity
|
At high fan speed
|
kW
|
2.5
|
3.2
|
4
|
5
|
6.3
|
8
|
Power input - 50Hz
|
Cooling
|
At high fan speed
|
kW
|
0.026
|
0.026
|
0.039
|
0.047
|
0.073
|
0.118
|
|
Heating
|
At high fan speed
|
kW
|
0.034
|
0.034
|
0.039
|
0.047
|
0.073
|
0.118
|
Dimensions
|
Unit
|
Height
|
mm
|
200
|
200
|
200
|
200
|
200
|
200
|
|
|
Width
|
mm
|
840
|
840
|
840
|
1240
|
1240
|
1240
|
|
|
Depth
|
mm
|
470
|
470
|
470
|
470
|
470
|
470
|
Weight
|
Unit
|
kg
|
18
|
18
|
19
|
24
|
24
|
24
|
Casing
|
Colour
|
|
Not painted (galvanised)
|
Not painted (galvanised)
|
Not painted (galvanised)
|
Not painted (galvanised)
|
Not painted (galvanised)
|
Not painted (galvanised)
|
|
Material
|
|
Galvanised steel
|
Galvanised steel
|
Galvanised steel
|
Galvanised steel
|
Galvanised steel
|
Galvanised steel
|
Fan
|
Air flow rate - 50Hz
|
Cooling
|
At high fan speed
|
m³/min
|
7.5
|
7.5
|
9.4
|
14.4
|
17.6
|
21.5
|
|
|
|
At low fan speed
|
m³/min
|
5
|
5
|
7.6
|
11.1
|
12.6
|
14.4
|
Refrigerant
|
Type
|
|
R-32
|
R-32
|
R-32
|
R-32
|
R-32
|
R-32
|
|
GWP
|
|
675
|
675
|
675
|
675
|
675
|
675
|
Sound power level
|
Cooling
|
At high fan speed
|
dBA
|
46
|
46
|
50.5
|
52.5
|
57
|
61.5
|
Sound pressure level
|
Cooling
|
At high fan speed
|
dBA
|
32
|
32
|
37
|
38.5
|
42
|
48.5
|
|
|
At medium fan speed
|
dBA
|
27.5
|
27.5
|
34
|
34.5
|
38
|
43.5
|
|
|
At low fan speed
|
dBA
|
22.5
|
22.5
|
31.5
|
31.5
|
34.5
|
38.5
|
|
Heating
|
At high fan speed
|
dBA
|
36
|
36
|
39
|
39.5
|
44
|
49
|
|
|
At medium fan speed
|
dBA
|
31
|
31
|
35.5
|
36
|
39.5
|
44
|
|
|
At low fan speed
|
dBA
|
25.5
|
25.5
|
32.5
|
32.5
|
36
|
39.5
|
Piping connections
|
Liquid
|
Type
|
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
|
|
OD
|
mm
|
6.4
|
6.4
|
6.4
|
6.4
|
6.4
|
6.4
|
|
Gas
|
Type
|
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
|
|
OD
|
mm
|
9.5
|
9.5
|
9.5
|
12.7
|
12.7
|
12.7
|
|
Drain
|
|
I.D. 20/O.D. 26
|
I.D. 20/O.D. 26
|
I.D. 20/O.D. 26
|
I.D. 20/O.D. 26
|
I.D. 20/O.D. 26
|
I.D. 20/O.D. 26
|
Decoration panel
|
Model
|
|
BYK32GJW1
|
BYK32GJW1
|
BYK32GJW1
|
BYK63GJW1
|
BYK63GJW1
|
BYK63GJW1
|
|
Colour
|
|
Fresh White
|
Fresh White
|
Fresh White
|
Fresh White
|
Fresh White
|
Fresh White
|
|
Dimensions
|
Height
|
mm
|
80
|
80
|
80
|
80
|
80
|
80
|
|
|
Width
|
mm
|
950
|
950
|
950
|
1350
|
1350
|
1350
|
|
|
Depth
|
mm
|
550
|
550
|
550
|
550
|
550
|
550
|
|
Weight
|
kg
|
8
|
8
|
8
|
10
|
10
|
10
|
Air filter
|
Type
|
|
Removable / washable
|
Removable / washable
|
Removable / washable
|
Removable / washable
|
Removable / washable
|
Removable / washable
|
Power supply
|
Name
|
|
VE
|
VE
|
VE
|
VE
|
VE
|
VE
|
|
Phase
|
|
1~
|
1~
|
1~
|
1~
|
1~
|
1~
|
|
Power supply-=-Frequency
|
Frequency
|
|
50/60
|
50/60
|
50/60
|
50/60
|
50/60
|
50/60
|
|
Power supply-=-Voltage
|
Voltage
|
|
220-240/220
|
220-240/220
|
220-240/220
|
220-240/220
|
220-240/220
|
220-240/220
|
Current - 50Hz
|
Current - 50Hz-=-Maximum fuse amps (MFA)
|
Maximum fuse amps (MFA)
|
|
6
|
6
|
6
|
6
|
6
|
6
|
Required ceiling void >
|
mm
|
260
|
260
|
260
|
260
|
260
|
260
|
Standard Accessories
|
General safety precautions
|
1
|
1
|
1
|
1
|
1
|
1
|
|
Sealing material (drain hose)
|
1
|
1
|
1
|
1
|
1
|
1
|
|
Clamp for drain hose
|
1
|
1
|
1
|
1
|
1
|
1
|
|
Drain hose
|
1
|
1
|
1
|
1
|
1
|
1
|
|
Installation and operation manual
|
1
|
1
|
1
|
1
|
1
|
1
|
|
Paper pattern for installation
|
1
|
1
|
1
|
1
|
1
|
1
|
Notes
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(3) - The sound power level is an absolute value indicating the power which a sound source generates.
|
(3) - The sound power level is an absolute value indicating the power which a sound source generates.
|
(3) - The sound power level is an absolute value indicating the power which a sound source generates.
|
(3) - The sound power level is an absolute value indicating the power which a sound source generates.
|
(3) - The sound power level is an absolute value indicating the power which a sound source generates.
|
(3) - The sound power level is an absolute value indicating the power which a sound source generates.
|
|
(4) - Instead of a fuse, use a circuit breaker
|
(4) - Instead of a fuse, use a circuit breaker
|
(4) - Instead of a fuse, use a circuit breaker
|
(4) - Instead of a fuse, use a circuit breaker
|
(4) - Instead of a fuse, use a circuit breaker
|
(4) - Instead of a fuse, use a circuit breaker
|
|
(5) - Select wire size based on the value of MCA
|
(5) - Select wire size based on the value of MCA
|
(5) - Select wire size based on the value of MCA
|
(5) - Select wire size based on the value of MCA
|
(5) - Select wire size based on the value of MCA
|
(5) - Select wire size based on the value of MCA
|