| FXLQ20P5VEB | FXLQ25P5VEB | FXLQ32P5VEB | FXLQ40P5VEB | FXLQ40P2VEB | FXLQ50P5VEB | FXLQ63P5VEB | FXLQ20P2VEB (Archived) | FXLQ25P2VEB (Archived) | FXLQ32P2VEB (Archived) | FXLQ50P2VEB (Archived) | FXLQ63P2VEB (Archived) | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Sound pressure level | Heating | At high fan speed | dBA | 35 | 35 | 35 | 38 | 38 | 39 | 40 | 35 | 35 | 35 | 39 | 40 | |
| At low fan speed | dBA | 32 | 32 | 32 | 33 | 33 | 34 | 35 | 32 | 32 | 32 | 34 | 35 | |||
| Cooling | At low fan speed | dBA | 32 | 32 | 32 | 33 | 33 | 34 | 35 | 32 | 32 | 32 | 34 | 35 | ||
| At high fan speed | dBA | 35 | 35 | 35 | 38 | 38 | 39 | 40 | 35 | 35 | 35 | 39 | 40 | |||
| Refrigerant | GWP | 2,087.5 | 2,087.5 | 2,087.5 | 2,087.5 | 2,087.5 | 2,087.5 | 2,087.5 | 2,087.5 | 2,087.5 | 2,087.5 | 2,087.5 | 2,087.5 | |||
| Type | R-410A | R-410A | R-410A | R-410A | R-410A | R-410A | R-410A | R-410A | R-410A | R-410A | R-410A | R-410A | ||||
| Power input - 50Hz | Cooling | At high fan speed | kW | 0.05 (1) | 0.05 (1) | 0.09 (1) | 0.09 (1) | 0.090 (1) | 0.11 (1) | 0.11 (1) | 0.05 (1) | 0.05 (1) | 0.09 (1) | 0.11 (1) | 0.11 (1) | |
| Heating | At high fan speed | kW | 0.05 (2) | 0.05 (2) | 0.09 (2) | 0.09 (2) | 0.090 (2) | 0.11 (2) | 0.11 (2) | 0.05 (2) | 0.05 (2) | 0.09 (2) | 0.11 (2) | 0.11 (2) | ||
| Cooling capacity | Total capacity | At high fan speed | kW | 2.2 (1) | 2.8 (1) | 3.6 (1) | 4.5 (1) | 4.5 (1) | 5.6 (1) | 7.1 (1) | 2.2 (1) | 2.8 (1) | 3.6 (1) | 5.6 (1) | 7.1 (1) | |
| Piping connections | Liquid | OD | mm | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 9.52 | |
| Type | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | ||||
| Gas | OD | mm | 12.7 | 12.7 | 12.7 | 12.7 | 12.7 | 12.7 | 15.9 | 12.7 | 12.7 | 12.7 | 12.7 | 15.9 | ||
| Type | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | ||||
| Drain | O.D. 21 (Vinyl chloride) | O.D. 21 (Vinyl chloride) | O.D. 21 (Vinyl chloride) | O.D. 21 (Vinyl chloride) | O.D. 21 (Vinyl chloride) | O.D. 21 (Vinyl chloride) | O.D. 21 (Vinyl chloride) | O.D. 21 (Vinyl chloride) | O.D. 21 (Vinyl chloride) | O.D. 21 (Vinyl chloride) | O.D. 21 (Vinyl chloride) | O.D. 21 (Vinyl chloride) | ||||
| Sound power level | Cooling | At high fan speed | dBA | 54 | 54 | 54 | 57 | 58 | 59 | 54 | 54 | 54 | 58 | 59 | ||
| Air filter | Type | Resin net | Resin net | Resin net | Resin net | Resin net | Resin net | Resin net | Resin net | Resin net | Resin net | Resin net | Resin net | |||
| Dimensions | Unit | Width | mm | 1,000 | 1,000 | 1,140 | 1,140 | 1,140 | 1,420 | 1,420 | 1,000 | 1,000 | 1,140 | 1,420 | 1,420 | |
| Depth | mm | 232 | 232 | 232 | 232 | 232 | 232 | 232 | 232 | 232 | 232 | 232 | 232 | |||
| Height | mm | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | |||
| Casing | Colour | Fresh white (RAL9010) / Dark grey (RAL7012) | Fresh white (RAL9010) / Dark grey (RAL7012) | Fresh white (RAL9010) / Dark grey (RAL7012) | Fresh white (RAL9010) / Dark grey (RAL7012) | Fresh white (RAL9010) / Dark grey (RAL7011) | Fresh white (RAL9010) / Dark grey (RAL7012) | Fresh white (RAL9010) / Dark grey (RAL7012) | Fresh white (RAL9010) / Dark grey (RAL7011) | Fresh white (RAL9010) / Dark grey (RAL7011) | Fresh white (RAL9010) / Dark grey (RAL7011) | Fresh white (RAL9010) / Dark grey (RAL7011) | Fresh white (RAL9010) / Dark grey (RAL7011) | |||
| Weight | Unit | kg | 27 | 27 | 32 | 32 | 32 | 38 | 38 | 27 | 27 | 32 | 38 | 38 | ||
| Fan | Air flow rate - 50Hz | Cooling | At high fan speed | m³/min | 7 | 7 | 8 | 11 | 11 | 14 | 16 | 7 | 7 | 8 | 14 | 16 |
| At low fan speed | m³/min | 6.0 | 6.0 | 6.0 | 8.5 | 8.5 | 11.0 | 12.0 | 6.0 | 6.0 | 6.0 | 11.0 | 12.0 | |||
| Air flow rate - 60Hz | Cooling | High | m³/min | 11 | ||||||||||||
| Low | m³/min | 8.5 | ||||||||||||||
| Heating capacity | Total capacity | At high fan speed | kW | 2.5 (2) | 3.2 (2) | 4.0 (2) | 5.0 (2) | 5.0 (2) | 6.3 (2) | 8.0 (2) | 2.5 (2) | 3.2 (2) | 4.0 (2) | 6.3 (2) | 8.0 (2) | |
| Current - 50Hz | Maximum fuse amps (MFA) | A | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | ||
| Power supply | Phase | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | |||
| Name | VE | VE | VE | VE | VE | VE | VE | VE | VE | VE | VE | VE | ||||
| Frequency | Hz | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | |||
| Voltage | V | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | |||
| Notes | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) | ||||
| (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) | |||||
| (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | |||||
| (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | |||||
| (5) - Maximum allowable voltage range variation between phases is 2%. | (5) - Maximum allowable voltage range variation between phases is 2%. | (5) - Maximum allowable voltage range variation between phases is 2%. | (5) - Maximum allowable voltage range variation between phases is 2%. | (5) - Maximum allowable voltage range variation between phases is 2%. | (5) - Maximum allowable voltage range variation between phases is 2%. | (5) - Maximum allowable voltage range variation between phases is 2%. | (5) - Maximum allowable voltage range variation between phases is 2%. | (5) - Maximum allowable voltage range variation between phases is 2%. | (5) - Maximum allowable voltage range variation between phases is 2%. | (5) - Maximum allowable voltage range variation between phases is 2%. | (5) - Maximum allowable voltage range variation between phases is 2%. | |||||
| (6) - MCA/MFA: MCA = 1.25 x FLA | (6) - MCA/MFA: MCA = 1.25 x FLA | (6) - MCA/MFA: MCA = 1.25 x FLA | (6) - MCA/MFA: MCA = 1.25 x FLA | (6) - MCA/MFA: MCA = 1.25 x FLA | (6) - MCA/MFA: MCA = 1.25 x FLA | (6) - MCA/MFA: MCA = 1.25 x FLA | (6) - MCA/MFA: MCA = 1.25 x FLA | (6) - MCA/MFA: MCA = 1.25 x FLA | (6) - MCA/MFA: MCA = 1.25 x FLA | (6) - MCA/MFA: MCA = 1.25 x FLA | (6) - MCA/MFA: MCA = 1.25 x FLA | |||||
| (7) - MFA ≤ 4 x FLA | (7) - MFA ≤ 4 x FLA | (7) - MFA ≤ 4 x FLA | (7) - MFA ≤ 4 x FLA | (7) - MFA ≤ 4 x FLA | (7) - MFA ≤ 4 x FLA | (7) - MFA ≤ 4 x FLA | (7) - MFA ≤ 4 x FLA | (7) - MFA ≤ 4 x FLA | (7) - MFA ≤ 4 x FLA | (7) - MFA ≤ 4 x FLA | (7) - MFA ≤ 4 x FLA | |||||
| (8) - Next lower standard fuse rating minimum 15A | (8) - Next lower standard fuse rating minimum 15A | (8) - Next lower standard fuse rating minimum 15A | (8) - Next lower standard fuse rating minimum 15A | (8) - Next lower standard fuse rating minimum 15A | (8) - Next lower standard fuse rating minimum 15A | (8) - Next lower standard fuse rating minimum 15A | (8) - Next lower standard fuse rating minimum 15A | (8) - Next lower standard fuse rating minimum 15A | (8) - Next lower standard fuse rating minimum 15A | (8) - Next lower standard fuse rating minimum 15A | (8) - Next lower standard fuse rating minimum 15A | |||||
| (9) - Select wire size based on the value of MCA | (9) - Select wire size based on the value of MCA | (9) - Select wire size based on the value of MCA | (9) - Select wire size based on the value of MCA | (9) - Select wire size based on the value of MCA | (9) - Select wire size based on the value of MCA | (9) - Select wire size based on the value of MCA | (9) - Select wire size based on the value of MCA | (9) - Select wire size based on the value of MCA | (9) - Select wire size based on the value of MCA | (9) - Select wire size based on the value of MCA | (9) - Select wire size based on the value of MCA | |||||
| (10) - Contains fluorinated greenhouse gases | (10) - Contains fluorinated greenhouse gases | (10) - Contains fluorinated greenhouse gases | (10) - Contains fluorinated greenhouse gases | (10) - Instead of a fuse, use a circuit breaker | (10) - Contains fluorinated greenhouse gases | (10) - Contains fluorinated greenhouse gases | (10) - Instead of a fuse, use a circuit breaker | (10) - Instead of a fuse, use a circuit breaker | (10) - Instead of a fuse, use a circuit breaker | (10) - Instead of a fuse, use a circuit breaker | (10) - Instead of a fuse, use a circuit breaker | |||||
| (11) - Instead of a fuse, use a circuit breaker | (11) - Instead of a fuse, use a circuit breaker | (11) - Instead of a fuse, use a circuit breaker | (11) - Instead of a fuse, use a circuit breaker | (11) - Contains fluorinated greenhouse gases | (11) - Instead of a fuse, use a circuit breaker | (11) - Instead of a fuse, use a circuit breaker | (11) - Contains fluorinated greenhouse gases | (11) - Contains fluorinated greenhouse gases | (11) - Contains fluorinated greenhouse gases | (11) - Contains fluorinated greenhouse gases | (11) - Contains fluorinated greenhouse gases | |||||