| RXYN10B7Y1B | |||||
|---|---|---|---|---|---|
| Recommended combination | 4 x FXSN63B2VEB | ||||
| Recommended combination 2 | 4 x FXFN63B2VEB | ||||
| Cooling capacity | Prated,c | kW | 28.0 (1) | ||
| Heating capacity | Prated,h | kW | 28.0 (2) | ||
| Nom. | 6°CWB | kW | 28.00 (2) | ||
| COP at nom. capacity | 6°CWB | KW/KW | 294.00 (2) | ||
| SEER | 4.80 | ||||
| SEER recommended combination 2 | 4.80 | ||||
| SCOP | 3.50 | ||||
| SCOP recommended combination 2 | 3.50 | ||||
| Space cooling | A Condition (35°C - 27/19) | EERd | 1.88 | ||
| Pdc | kW | 28.0 | |||
| B Condition (30°C - 27/19) | EERd | 2.88 | |||
| Pdc | kW | 20.6 | |||
| C Condition (25°C - 27/19) | EERd | 6.40 | |||
| Pdc | kW | 13.3 | |||
| D Condition (20°C - 27/19) | EERd | 12.3 | |||
| Pdc | kW | 8.28 | |||
| Space cooling recommended combination 2 | A Condition (35°C - 27/19) | EERd | 1.88 | ||
| Pdc | kW | 28.0 | |||
| B Condition (30°C - 27/19) | EERd | 2.88 | |||
| Pdc | kW | 20.6 | |||
| C Condition (25°C - 27/19) | EERd | 6.40 | |||
| Pdc | kW | 13.3 | |||
| D Condition (20°C - 27/19) | EERd | 12.3 | |||
| Pdc | kW | 8.28 | |||
| Space heating (Average climate) | TBivalent | COPd (declared COP) | 1.53 | ||
| Pdh (declared heating cap) | kW | 16.0 | |||
| Tbiv (bivalent temperature) | °C | -10.0 | |||
| Space heating (Average climate)-=-E condition (-10°C) | Space heating (Average climate)-=-E condition (-10°C)-=-COPd (declared COP) | 1.53 | |||
| Space heating (Average climate)-=-E condition (-10°C)-=-Pdh (declared heating cap)-=-kW | kW | 16.0 | |||
| TOL | Tol (temperature operating limit) | °C | -10 | ||
| A Condition (-7°C) | COPd (declared COP) | 2.14 | |||
| Pdh (declared heating cap) | kW | 14.2 | |||
| B Condition (2°C) | COPd (declared COP) | 3.34 | |||
| Pdh (declared heating cap) | kW | 8.62 | |||
| C Condition (7°C) | COPd (declared COP) | 5.00 | |||
| Pdh (declared heating cap) | kW | 5.54 | |||
| D Condition (12°C) | COPd (declared COP) | 6.52 | |||
| Pdh (declared heating cap) | kW | 7.04 | |||
| Space heating (Average climate) recommended combination 2 | TBivalent | COPd (declared COP) | 1.53 | ||
| Pdh (declared heating cap) | kW | 16.0 | |||
| Tbiv (bivalent temperature) | °C | -10.0 | |||
| TOL | COPd (declared COP) | 1.53 | |||
| Pdh (declared heating cap) | kW | 16.0 | |||
| Tol (temperature operating limit) | °C | -10 | |||
| A Condition (-7°C) | COPd (declared COP) | 2.14 | |||
| Pdh (declared heating cap) | kW | 14.2 | |||
| B Condition (2°C) | COPd (declared COP) | 3.34 | |||
| Pdh (declared heating cap) | kW | 8.62 | |||
| C Condition (7°C) | COPd (declared COP) | 5.00 | |||
| Pdh (declared heating cap) | kW | 5.54 | |||
| D Condition (12°C) | COPd (declared COP) | 6.52 | |||
| Pdh (declared heating cap) | kW | 7.04 | |||
| Capacity range | HP | 10 | |||
| Maximum number of connectable indoor units | 8 (3) | ||||
| Indoor index connection | Min. | 125 | |||
| Max. | 325 | ||||
| Dimensions | Unit | Height | mm | 1,680 | |
| Width | mm | 1930 | |||
| Depth | mm | 765 | |||
| Weight | Unit | kg | 564 | ||
| Compressor | Type | Hermetically sealed swing compressor | |||
| Operation range | Cooling | Min. | °CDB | -5 | |
| Max. | °CDB | 43 | |||
| Heating | Min. | °CWB | -20 | ||
| Max. | °CWB | 16 | |||
| Sound power level | Cooling | Nom. | dBA | 835.0 (4) | |
| Sound pressure level | Cooling | Nom. | dBA | 608.0 (5) | |
| Refrigerant | Type | R744 (CO2) | |||
| GWP | 1.0 | ||||
| Charge | tCO2Eq | 0.00 | |||
| Charge | kg | 0.00 | |||
| Piping connections | Liquid | Type | Braze connection | ||
| OD | mm | 9.52 | |||
| Gas | Type | Braze connection | |||
| OD | mm | 15.9 | |||
| Total piping length | System | Actual | m | 300 (6) | |
| Standard Accessories | Installation manual | 1 | |||
| Auxiliary piping set | 1 | ||||
| General safety precautions | 1 | ||||
| Operation manual | 1 | ||||
| Safety valve | 2 | ||||
| Changeover valve | 1 | ||||
| Declaration of conformity | 1 | ||||
| Power supply | Name | Y1 | |||
| Phase | 3N~ | ||||
| Frequency | Hz | 50 | |||
| Voltage | V | 380-415 | |||
| Notes | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m | ||||
| (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m | |||||
| (3) - The actual number of units depends on the connection ratio (CR) and the restrictions for the system. | |||||
| (4) - Sound power level is an absolute value that a sound source generates. | |||||
| (5) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. | |||||
| (6) - Refer to refrigerant pipe selection or installation manual | |||||
| (7) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB | |||||
| (8) - MSC means the maximum current during start up of the compressor. This unit uses only inverter compressors. Starting current is always ≤ max. running current. | |||||
| (9) - In accordance with EN/IEC 61000-3-12, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply wih Ssc ≥ minimum Ssc value | |||||
| (10) - MCA must be used to select the correct field wiring size. The MCA can be regarded as the maximum running current. | |||||
| (11) - MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). | |||||
| (12) - Maximum allowable voltage range variation between phases is 2%. | |||||
| (13) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | |||||
| (14) - Sound values are measured in a semi-anechoic room. | |||||
| (15) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | |||||
| (16) - Ssc: Short-circuit power | |||||
| (17) - For detailed contents of standard accessories, see installation/operation manual | |||||