Specifications Table for RZAG-LV1

RZAG71L7V1B RZAG100L7V1B RZAG125L7V1B RZAG140L7V1B
Sound pressure level Heating Nom. dBA 50 51 52 52
  Cooling Nom. dBA 48 49 51 52
  Night quiet mode Level 1 dBA 43 45 45 45
Standard Accessories Tie-wraps 2 2 2 2
  Installation manual 1 1 1 1
Refrigerant Charge TCO2Eq 1.8 2.3 2.3 2.3
  GWP   675 675 675 675
  Charge kg 2.6 3.4 3.4 3.4
  Type   R-32 R-32 R-32 R-32
Piping connections Liquid OD mm 9.52 9.52 9.52 9.52
  Piping length OU - IU Max. m 55 85 85 85
    System Chargeless m 30 30 30 30
      Equivalent m 75 100 100 100
  Gas OD mm 15.9 15.9 15.9 15.9
  Level difference IU - IU Max. m 0.5 0.5 0.5 0.5
    IU - OU Max. m 30.0 30.0 30.0 30.0
  Additional refrigerant charge kg/m See installation manual See installation manual See installation manual See installation manual
Sound power level Cooling dBA 64 64 66 67
Dimensions Unit Width mm 940 940 940 940
    Depth mm 320 320 320 320
    Height mm 990 1,430 1,430 1,430
Compressor Type   Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor
Weight Unit kg 67 93 93 93
Power supply Phase   1~ 1~ 1~ 1~
  Frequency Hz 50/60 50/60 50/60 50/60
  Voltage V 220-240 220-240 220-240 220-240
Notes (1) - Contains fluorinated greenhouse gases (1) - Contains fluorinated greenhouse gases (1) - Contains fluorinated greenhouse gases (1) - Contains fluorinated greenhouse gases
  (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series
  (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data