| VAM350J7VEB | VAM500J7VEB | VAM650J7VEB | VAM800J7VEB | VAM1000J7VEB | VAM1500J7VEB | VAM2000J7VEB | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Operation range | Min. | °CDB | -10 (2) | -10 (2) | -10 (2) | -10 (2) | -10 (2) | -10 (2) | |||
| Max. | °CDB | 46 | 46 | 46 | 46 | 46 | 46 | ||||
| Around unit | °CDB | 0°C~40°CDB, 80% RH or less | 0°C~40°CDB, 80% RH or less | 0°C~40°CDB, 80% RH or less | 0°C~40°CDB, 80% RH or less | 0°C~40°CDB, 80% RH or less | 0°C~40°CDB, 80% RH or less | ||||
| Relative humidity | % | 80 or less | 80 or less | 80 or less | 80 or less | 80 or less | 80 or less | ||||
| Weight | Unit | kg | 46.5 | 61.5 | 76.5 | 76.5 | 160 | 160 | |||
| Heat exchange system | Air to air cross flow total heat (sensible + latent heat) exchange | Air to air cross flow total heat (sensible + latent heat) exchange | Air to air cross flow total heat (sensible + latent heat) exchange | Air to air cross flow total heat (sensible + latent heat) exchange | Air to air cross flow total heat (sensible + latent heat) exchange | Air to air cross flow total heat (sensible + latent heat) exchange | |||||
| Operation mode | Heat exchange mode, bypass mode, fresh-up mode | Heat exchange mode, bypass mode, fresh-up mode | Heat exchange mode, bypass mode, fresh-up mode | Heat exchange mode, bypass mode, fresh-up mode | Heat exchange mode, bypass mode, fresh-up mode | Heat exchange mode, bypass mode, fresh-up mode | |||||
| Sound power level (Lwa) | dB | 51 | 54 | 58 | 58 | 61 | 62 | 65 | |||
| Power input - 50Hz | Heat exchange mode | Nom. | Ultra high | kW | 0.164 (1) | 0.247 (1) | 0.303 (1) | 0.416 (1) | 0.548 (1) | 0.833 (1) | |
| Bypass mode | Nom. | Ultra high | kW | 0.148 (1) | 0.195 (1) | 0.289 (1) | 0.417 (1) | 0.525 (1) | 0.835 (1) | ||
| Heat exchange element | Specially processed non-flammable paper | Specially processed non-flammable paper | Specially processed non-flammable paper | Specially processed non-flammable paper | Specially processed non-flammable paper | Specially processed non-flammable paper | |||||
| Sound pressure level - 50Hz | Heat exchange mode | Ultra high | dBA | 37.5 (1) | 39.0 (1) | 42.0 (1) | 42.0 (1) | 45.0 (1) | |||
| Bypass mode | Ultra high | dBA | 38.0 (1) | 40.0 (1) | 42.5 (1) | 42.0 (1) | 45.0 (1) | ||||
| Dimensions | Unit | Width | mm | 1,113 | 1,354 | 1,354 | 1,354 | 1,354 | 1,354 | ||
| Depth | mm | 866 | 920 | 1,172 | 1,172 | 1,172 | 1,172 | ||||
| Height | mm | 305 | 368 | 368 | 368 | 731 | 731 | ||||
| Casing | Material | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | ||||
| Fan | External static pressure - 50Hz | Ultra high | Pa | 90.0 (1) | 90.0 (1) | 90.0 (1) | 90.0 (1) | 90.0 (1) | 90.0 (1) | ||
| Air flow rate - 50Hz | Heat exchange mode | Ultra high | m³/h | 500 (1) | 650 (1) | 800 (1) | 1,000 (1) | 1,500 (1) | 2,000 (1) | ||
| Bypass mode | Ultra high | m³/h | 500 (1) | 650 (1) | 800 (1) | 1,000 (1) | 1,500 (1) | 2,000 (1) | |||
| Connection duct diameter | mm | 200 | 250 | 250 | 250 | 2x250 | 2x250 | ||||
| Power supply | Phase | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | ||||
| Name | VE | VE | VE | VE | VE | VE | |||||
| Frequency | Hz | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | ||||
| Voltage | V | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | ||||
| Notes | (1) - Measured according to JIS B 8628 - 2003 | (1) - Measured according to JIS B 8628 - 2003 | (1) - Measured according to JIS B 8628 - 2003 | (1) - Measured according to JIS B 8628 - 2003 | (1) - Measured according to JIS B 8628 - 2003 | (1) - Measured according to JIS B 8628 - 2003 | (1) - Measured according to JIS B 8628 - 2003 | ||||
| (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | |||||
| (3) - In accordance with commission regulation (EU) No 1253/2014 | (3) - In accordance with commission regulation (EU) No 1253/2014 | (3) - In accordance with commission regulation (EU) No 1253/2014 | (3) - In accordance with commission regulation (EU) No 1253/2014 | (3) - In accordance with commission regulation (EU) No 1253/2014 | (3) - In accordance with commission regulation (EU) No 1253/2014 | (3) - In accordance with commission regulation (EU) No 1253/2014 | |||||
| (4) - Measured according to EN308 : 1997 | (4) - Measured according to EN308 : 1997 | (4) - Measured according to EN308 : 1997 | (4) - Measured according to EN308 : 1997 | (4) - Measured according to EN308 : 1997 | (4) - Measured according to EN308 : 1997 | (4) - Measured according to EN308 : 1997 | |||||
| (5) - In accordance with regulation (EU) No 327/2011 | (5) - Clean the filter when the filter icon appears on the controller screen. Regular filter cleaning is important for delivered air quality and for the unit's energy efficiency. | (5) - Clean the filter when the filter icon appears on the controller screen. Regular filter cleaning is important for delivered air quality and for the unit's energy efficiency. | (5) - Clean the filter when the filter icon appears on the controller screen. Regular filter cleaning is important for delivered air quality and for the unit's energy efficiency. | (5) - Clean the filter when the filter icon appears on the controller screen. Regular filter cleaning is important for delivered air quality and for the unit's energy efficiency. | (5) - Clean the filter when the filter icon appears on the controller screen. Regular filter cleaning is important for delivered air quality and for the unit's energy efficiency. | (5) - Clean the filter when the filter icon appears on the controller screen. Regular filter cleaning is important for delivered air quality and for the unit's energy efficiency. | |||||
| (6) - In accordance with regulation (EU) No 327/2011 | (6) - In accordance with regulation (EU) No 327/2011 | (6) - In accordance with regulation (EU) No 327/2011 | (6) - In accordance with regulation (EU) No 327/2011 | (6) - In accordance with regulation (EU) No 327/2011 | (6) - In accordance with regulation (EU) No 327/2011 | ||||||
| (7) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (7) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (7) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (7) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (7) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (7) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | ||||||
| (8) - MCA= 1,25x(FLA(FM1)+FLA(FM2)+FLA(FM3)+FLA(FM4)) | (8) - MCA= 1,25x(FLA(FM1)+FLA(FM2)+FLA(FM3)+FLA(FM4)) | (8) - MCA= 1,25x(FLA(FM1)+FLA(FM2)+FLA(FM3)+FLA(FM4)) | (8) - MCA= 1,25x(FLA(FM1)+FLA(FM2)+FLA(FM3)+FLA(FM4)) | (8) - MCA= 1,25x(FLA(FM1)+FLA(FM2)+FLA(FM3)+FLA(FM4)) | (8) - MCA= 1,25x(FLA(FM1)+FLA(FM2)+FLA(FM3)+FLA(FM4)) | ||||||
| (9) - MCA represents maximum input current. | (9) - MCA represents maximum input current. | (9) - MCA represents maximum input current. | (9) - MCA represents maximum input current. | (9) - MCA represents maximum input current. | (9) - MCA represents maximum input current. | ||||||
| (10) - MFA ≤ 4 x (FLA(FM1)+FLA(FM2)+...) | (10) - MFA ≤ 4 x (FLA(FM1)+FLA(FM2)+...) | (10) - MFA ≤ 4 x (FLA(FM1)+FLA(FM2)+...) | (10) - MFA ≤ 4 x (FLA(FM1)+FLA(FM2)+...) | (10) - MFA ≤ 4 x (FLA(FM1)+FLA(FM2)+...) | (10) - MFA ≤ 4 x (FLA(FM1)+FLA(FM2)+...) | ||||||
| (11) - Select wire size based on the value of MCA | (11) - Select wire size based on the value of MCA | (11) - Select wire size based on the value of MCA | (11) - Select wire size based on the value of MCA | (11) - Select wire size based on the value of MCA | (11) - Select wire size based on the value of MCA | ||||||
| (12) - Fan step 8 is nominal specs. | (12) - Fan step 8 is nominal specs. | (12) - Fan step 8 is nominal specs. | (12) - Fan step 8 is nominal specs. | (12) - Fan step 8 is nominal specs. | (12) - Fan step 8 is nominal specs. | ||||||
| (13) - The unit complies for "Code du travail" and "ERP 5e catégorie" applications according to French legislation. | (13) - The unit complies for "Code du travail" and "ERP 5e catégorie" applications according to French legislation. | (13) - The unit complies for "Code du travail" and "ERP 5e catégorie" applications according to French legislation. | (13) - The unit complies for "Code du travail" and "ERP 5e catégorie" applications according to French legislation. | (13) - The unit complies for "Code du travail" and "ERP 5e catégorie" applications according to French legislation. | (13) - The unit complies for "Code du travail" and "ERP 5e catégorie" applications according to French legislation. | ||||||
| (14) - "Code du travail" applications are non-public buildings (example offices). | (14) - "Code du travail" applications are non-public buildings (example offices). | (14) - "Code du travail" applications are non-public buildings (example offices). | (14) - "Code du travail" applications are non-public buildings (example offices). | (14) - "Code du travail" applications are non-public buildings (example offices). | (14) - "Code du travail" applications are non-public buildings (example offices). | ||||||
| (15) - "ERP (Etablissement Recevant du Public) de 5e catégorie" are smaller shops, hotels etc | (15) - "ERP (Etablissement Recevant du Public) de 5e catégorie" are smaller shops, hotels etc | (15) - "ERP (Etablissement Recevant du Public) de 5e catégorie" are smaller shops, hotels etc | (15) - "ERP (Etablissement Recevant du Public) de 5e catégorie" are smaller shops, hotels etc | (15) - "ERP (Etablissement Recevant du Public) de 5e catégorie" are smaller shops, hotels etc | (15) - "ERP (Etablissement Recevant du Public) de 5e catégorie" are smaller shops, hotels etc | ||||||
| Power input - 50Hz | Heat exchange mode | Nom. | Ultra high | kW | 0.097 (1) | ||||||
| Bypass mode | Nom. | Ultra high | kW | 0.085 (1) | |||||||
| Dimensions | Unit | Height | mm | 305 | |||||||
| Width | mm | 1113 | |||||||||
| Depth | mm | 866 | |||||||||
| Weight | Unit | kg | 46.5 | ||||||||
| Fan | Air flow rate - 50Hz | Heat exchange mode | Ultra high | m³/h | 350 (1) | ||||||
| Bypass mode | Ultra high | m³/h | 350 (1) | ||||||||
| External static pressure - 50Hz | Ultra high | Pa | 90.0 (1) | ||||||||
| Operation range | Min. | °CDB | -10 (2) | ||||||||
| Max. | °CDB | 46 | |||||||||
| Sound pressure level - 50Hz | Heat exchange mode | Ultra high | dBA | 34.5 (1) | |||||||
| Bypass mode | Ultra high | dBA | 34.5 (1) | ||||||||
| Power supply | Phase | 1~ | |||||||||
| Frequency | Hz | 50/60 | |||||||||
| Voltage | V | 220-240/220 | |||||||||
| Sound pressure level - 50Hz | Heat exchange mode | Ultra high | dBA | 39.0 (1) | |||||||
| Bypass mode | Ultra high | dBA | 38.0 (1) | ||||||||