RQEQ140PY13 |
RQEQ180PY13 |
RQEQ212PY13 |
Cooling capacity |
Prated,c |
kW |
14.0 |
18.0 |
20.0 |
|
Nom. |
kW |
14.0 (1) |
18.0 (1) |
21.2 (1) |
Heating capacity |
Prated,h |
kW |
16.0 |
20.0 |
22.4 |
|
Nom. |
kW |
16.0 (2) |
20.0 (2) |
22.4 (2) |
Space cooling |
A Condition (35°C - 27/19) |
EERd |
|
2.54 |
2.22 |
1.74 |
|
|
Pdc |
kW |
14.0 |
18.0 |
20.0 |
|
B Condition (30°C - 27/19) |
EERd |
|
4.40 |
3.86 |
3.63 |
|
|
Pdc |
kW |
10.3 |
13.3 |
14.7 |
|
C Condition (25°C - 27/19) |
EERd |
|
7.31 |
6.89 |
6.57 |
|
|
Pdc |
kW |
6.63 |
8.53 |
9.47 |
|
D Condition (20°C - 27/19) |
EERd |
|
9.29 |
9.54 |
9.64 |
|
|
Pdc |
kW |
5.01 |
4.94 |
4.95 |
Space heating (Average climate) |
TBivalent |
COPd (declared COP) |
|
1.92 |
1.84 |
1.64 |
|
|
Pdh (declared heating cap) |
kW |
8.5 |
10.6 |
11.9 |
|
|
Tbiv (bivalent temperature) |
°C |
-10 |
-10 |
-10 |
|
TOL |
COPd (declared COP) |
|
1.92 |
1.84 |
1.64 |
|
|
Pdh (declared heating cap) |
kW |
8.5 |
10.6 |
11.9 |
|
A Condition (-7°C) |
COPd (declared COP) |
|
2.20 |
2.22 |
2.20 |
|
|
Pdh (declared heating cap) |
kW |
7.52 |
9.40 |
10.5 |
|
B Condition (2°C) |
COPd (declared COP) |
|
3.42 |
3.56 |
3.92 |
|
|
Pdh (declared heating cap) |
kW |
4.58 |
5.72 |
6.41 |
|
C Condition (7°C) |
COPd (declared COP) |
|
4.84 |
5.26 |
5.40 |
|
|
Pdh (declared heating cap) |
kW |
3.29 |
3.68 |
4.12 |
|
D Condition (12°C) |
COPd (declared COP) |
|
6.43 |
6.82 |
6.88 |
|
|
Pdh (declared heating cap) |
kW |
4.18 |
4.40 |
4.44 |
Dimensions |
Unit |
Height |
mm |
1,680 |
1,680 |
1,680 |
|
|
Width |
mm |
635 |
635 |
635 |
|
|
Depth |
mm |
765 |
765 |
765 |
Weight |
Unit |
kg |
175 |
175 |
179 |
Compressor |
Type |
|
Hermetically sealed scroll compressor |
Hermetically sealed scroll compressor |
Hermetically sealed scroll compressor |
Operation range |
Cooling |
Min. |
°CDB |
-5 |
-5 |
-5 |
|
|
Max. |
°CDB |
43 |
43 |
43 |
|
Heating |
Min. |
°CWB |
-20 |
-20 |
-20 |
|
|
Max. |
°CWB |
15.5 |
15.5 |
15.5 |
Sound power level |
Cooling |
Nom. |
dBA |
79 |
83 |
87 |
Refrigerant |
Type |
|
R-410A |
R-410A |
R-410A |
|
GWP |
|
2,087.5 |
2,087.5 |
2,087.5 |
|
Charge |
kg |
10.3 |
10.6 |
11.2 |
|
Charge |
TCO2Eq |
21.5 |
22.1 |
23.4 |
Piping connections |
Liquid |
Type |
|
Braze connection |
Braze connection |
Braze connection |
|
|
OD |
mm |
9.52 |
9.52 |
9.52 |
|
Gas |
Type |
|
Braze connection |
Braze connection |
Braze connection |
|
|
OD |
mm |
15.9 |
19.1 |
19.1 |
|
Discharge gas |
OD |
mm |
12.7 |
15.9 |
15.9 |
|
|
Type |
|
Braze connection |
Braze connection |
Braze connection |
Power supply |
Name |
|
Y1 |
Y1 |
Y1 |
|
Phase |
|
3~ |
3~ |
3~ |
|
Frequency |
Hz |
50 |
50 |
50 |
|
Voltage |
V |
380-415 |
380-415 |
380-415 |
Notes |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m |
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m |
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m |
|
(3) - Sound values are measured in an anechoic chamber. Operating sound level generally becomes higher than this value depending on the operating conditions, reflected sound, and peripheral noise. |
(3) - Sound values are measured in an anechoic chamber. Operating sound level generally becomes higher than this value depending on the operating conditions, reflected sound, and peripheral noise. |
(3) - Sound values are measured in an anechoic chamber. Operating sound level generally becomes higher than this value depending on the operating conditions, reflected sound, and peripheral noise. |
|
(4) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB |
(4) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB |
(4) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB |
|
(5) - TOCA means the total value of each OC set. |
(5) - TOCA means the total value of each OC set. |
(5) - TOCA means the total value of each OC set. |
|
(6) - MSC means the maximum current during start up of the compressor |
(6) - MSC means the maximum current during start up of the compressor |
(6) - MSC means the maximum current during start up of the compressor |
|
(7) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. |
(7) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. |
(7) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. |
|
(8) - Maximum allowable voltage range variation between phases is 2%. |
(8) - Maximum allowable voltage range variation between phases is 2%. |
(8) - Maximum allowable voltage range variation between phases is 2%. |
|
(9) - Select wire size based on the larger value of MCA or TOCA |
(9) - Select wire size based on the larger value of MCA or TOCA |
(9) - Select wire size based on the larger value of MCA or TOCA |
|
(10) - MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). |
(10) - MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). |
(10) - MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). |
|
(11) - Contains fluorinated greenhouse gases |