Specifications Table for RXG-L

RXG20L2V1B RXG25L2V1B RXG35L2V1B RXG50L2V1B
Dimensions Unit Height mm 550 550 550 735
    Width mm 765 765 765 825
    Depth mm 285 285 285 300
Weight Unit kg 35 35 35 48
Compressor Type   Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor
Fan Air flow rate Cooling Super low cfm 1,094 1,094 1,094 1,504
    Heating Super low cfm 932 932 932 1,352
Fan motor Speed Cooling Super low rpm 780 780 780 670
    Heating Super low rpm 740 740 740 670
Sound pressure level Cooling High dBA 46 46 48 48
  Heating High dBA 47 47 48 48
Refrigerant Type   R-410A R-410A R-410A R-410A
  Charge kg 1.05 1.05 1.05 1.6
  Charge TCO2Eq 2.2 2.2 2.2 3.3
  GWP   2,087.5 2,087.5 2,087.5 2,087.5
Piping connections Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m)
  Level difference IU - OU Max. m 15 15 15 20
Standard Accessories Joint (drain) 1 1 1 1
  Installation manual 1 1 1 1
Power supply Phase   1~ 1~ 1~ 1~
  Frequency Hz 50 50 50 50
  Voltage V 220-240 220-240 220-240 220-240
Notes (1) - SL: The silent fan level of the air flow rate setting (1) - SL: The silent fan level of the air flow rate setting (1) - SL: The silent fan level of the air flow rate setting (1) - SL: The silent fan level of the air flow rate setting
  (2) - 220V (2) - 220V (2) - 220V (2) - 220V
  (3) - 230V (3) - 230V (3) - 230V (3) - 230V
  (4) - 240V (4) - 240V (4) - 240V (4) - 240V
  (5) - Operation range in combination with Nexura, FVXG-K, cooling: min. 10°CDB - max. 46°CDB; heating: min. -15°CWB - max. 18°CWB (5) - Operation range in combination with Nexura, FVXG-K, cooling: min. 10°CDB - max. 46°CDB; heating: min. -15°CWB - max. 18°CWB (5) - Operation range in combination with Nexura, FVXG-K, cooling: min. 10°CDB - max. 46°CDB; heating: min. -15°CWB - max. 18°CWB (5) - Operation range in combination with Nexura, FVXG-K, cooling: min. 10°CDB - max. 46°CDB; heating: min. -15°CWB - max. 18°CWB
  (6) - Contains fluorinated greenhouse gases (6) - Contains fluorinated greenhouse gases (6) - Contains fluorinated greenhouse gases (6) - Contains fluorinated greenhouse gases