RXJ20M5V1B |
RXJ25M5V1B |
RXJ35M5V1B |
RXJ50MV1B |
RXJ20M3V1B (Archived) |
RXJ20M2V1B (Archived) |
RXJ25M3V1B (Archived) |
RXJ25M2V1B (Archived) |
RXJ35M3V1B (Archived) |
RXJ35M2V1B (Archived) |
Dimensions |
Unit |
Height |
mm |
550 |
550 |
550 |
735 |
550 |
550 |
550 |
550 |
550 |
550 |
|
|
Width |
mm |
765 |
765 |
765 |
825 |
765 |
765 |
765 |
765 |
765 |
765 |
|
|
Depth |
mm |
285 |
285 |
285 |
300 |
285 |
285 |
285 |
285 |
285 |
285 |
Weight |
Unit |
kg |
32 |
32 |
32 |
44 |
32 |
34 |
32 |
34 |
32 |
34 |
Compressor |
Type |
|
Hermetically sealed swing compressor |
Hermetically sealed swing compressor |
Hermetically sealed swing compressor |
|
|
|
Hermetically sealed swing compressor |
|
Hermetically sealed swing compressor |
|
Fan |
Air flow rate |
Cooling |
Super low |
cfm |
|
|
|
1,359 |
|
1,035 |
|
1,035 |
|
1,035 |
|
|
|
Super low |
m³/min |
|
|
|
38.5 |
|
29.3 |
|
29.3 |
|
29.3 |
|
|
Heating |
Super low |
cfm |
|
|
|
1,211 |
|
904 |
|
904 |
|
904 |
|
|
|
Super low |
m³/min |
|
|
|
34.3 |
|
25.6 |
|
25.6 |
|
25.6 |
Operation range |
Cooling |
Ambient |
Min. |
°CDB |
|
|
|
-10 |
|
-10 |
|
-10 |
|
-10 |
|
|
|
Max. |
°CDB |
|
|
|
46 |
|
46 |
|
46 |
|
46 |
|
Heating |
Ambient |
Min. |
°CWB |
|
|
|
-15 |
|
-15 |
|
-15 |
|
-15 |
|
|
|
Max. |
°CWB |
|
|
|
18 |
|
18 |
|
18 |
|
18 |
Sound pressure level |
Cooling |
High |
dBA |
|
|
|
48 |
|
46 |
|
46 |
|
48 |
|
|
Nom. |
dBA |
46 |
46 |
49 |
|
46 |
|
46 |
|
49 |
|
|
Heating |
High |
dBA |
|
|
|
48 |
|
47 |
|
47 |
|
48 |
|
|
Nom. |
dBA |
47 |
47 |
49 |
|
47 |
|
47 |
|
49 |
|
Refrigerant |
Type |
|
R-32 |
R-32 |
R-32 |
R-32 |
R-32 |
R-32 |
R-32 |
R-32 |
R-32 |
R-32 |
|
Charge |
kg |
0.76 |
0.76 |
0.76 |
1.30 |
0.76 |
0.72 |
0.76 |
0.72 |
0.76 |
0.72 |
|
Charge |
TCO2Eq |
0.52 |
0.52 |
0.52 |
0.9 |
0.52 |
0.5 |
0.52 |
0.5 |
0.52 |
0.5 |
|
GWP |
|
675.0 |
675.0 |
675.0 |
675 |
675.0 |
675 |
675.0 |
675 |
675.0 |
675 |
Piping connections |
Additional refrigerant charge |
kg/m |
0.02 (for piping length exceeding 10m) |
0.02 (for piping length exceeding 10m) |
0.02 (for piping length exceeding 10m) |
|
|
|
0.02 (for piping length exceeding 10m) |
|
0.02 (for piping length exceeding 10m) |
|
|
Level difference |
IU - OU |
Max. |
m |
15.0 |
15.0 |
15.0 |
|
|
|
15.0 |
|
15.0 |
|
Power supply |
Phase |
|
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
|
Voltage |
V |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
Notes |
(1) - Contains fluorinated greenhouse gases |
(1) - Contains fluorinated greenhouse gases |
(1) - Contains fluorinated greenhouse gases |
(1) - SL: The silent fan level of the air flow rate setting |
(1) - Contains fluorinated greenhouse gases |
(1) - SL: The silent fan level of the air flow rate setting |
(1) - Contains fluorinated greenhouse gases |
(1) - SL: The silent fan level of the air flow rate setting |
(1) - Contains fluorinated greenhouse gases |
(1) - SL: The silent fan level of the air flow rate setting |
|
(2) - See separate drawing for operation range |
(2) - See separate drawing for operation range |
(2) - See separate drawing for operation range |
(2) - Contains fluorinated greenhouse gases |
(2) - See separate drawing for operation range |
(2) - Contains fluorinated greenhouse gases |
(2) - See separate drawing for operation range |
(2) - Contains fluorinated greenhouse gases |
(2) - See separate drawing for operation range |
(2) - Contains fluorinated greenhouse gases |
|
(3) - See separate drawing for electrical data |
(3) - See separate drawing for electrical data |
(3) - See separate drawing for electrical data |
(3) - 220V |
(3) - See separate drawing for electrical data |
(3) - 220V |
(3) - See separate drawing for electrical data |
(3) - 220V |
(3) - See separate drawing for electrical data |
(3) - 220V |
Fan motor |
Speed |
Cooling |
Super low |
rpm |
|
|
|
620 |
|
760 |
|
760 |
|
760 |
|
|
Heating |
Super low |
rpm |
|
|
|
620 |
|
740 |
|
740 |
|
740 |
Compressor |
Type |
|
|
|
|
Hermetically sealed swing compressor |
Hermetically sealed swing compressor |
Hermetically sealed swing compressor |
|
Hermetically sealed swing compressor |
|
Hermetically sealed swing compressor |
Piping connections |
Additional refrigerant charge |
kg/m |
|
|
|
0.02 (for piping length exceeding 10m) |
0.02 (for piping length exceeding 10m) |
0.02 (for piping length exceeding 10m) |
|
0.02 (for piping length exceeding 10m) |
|
0.02 (for piping length exceeding 10m) |
|
Level difference |
IU - OU |
Max. |
m |
|
|
|
20 |
15.0 |
15 |
|
15 |
|
15 |
Standard Accessories |
Drain plug |
|
|
|
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
Installation manual |
|
|
|
1 |
1 |
1 |
1 |
1 |
1 |
1 |
Notes |
|
|
|
(4) - 230V |
|
(4) - 230V |
|
(4) - 230V |
|
(4) - 230V |
|
|
|
|
(5) - 240V |
|
(5) - 240V |
|
(5) - 240V |
|
(5) - 240V |
Standard Accessories |
Refrigerant charge label |
|
|
|
|
1 |
|
1 |
|
1 |
|
|
Multilingual fluorinated greenhouse gases labels |
|
|
|
|
1 |
|
1 |
|
1 |
|
|
General safety precautions |
|
|
|
|
1 |
|
1 |
|
1 |
|