RZAG71M7Y1B |
RZAG100M7Y1B |
RZAG125M7Y1B |
RZAG140M7Y1B |
Dimensions |
Unit |
Height |
mm |
990 |
1,430 |
1,430 |
1,430 |
|
|
Width |
mm |
940 |
940 |
940 |
940 |
|
|
Depth |
mm |
320 |
320 |
320 |
320 |
Weight |
Unit |
kg |
70 |
92 |
92 |
92 |
Compressor |
Type |
|
Hermetically sealed swing compressor |
Hermetically sealed swing compressor |
Hermetically sealed swing compressor |
Hermetically sealed swing compressor |
Sound power level |
Cooling |
dBA |
65 |
66 |
69 |
70 |
|
Heating |
dBA |
|
|
69 (1) |
70 (1) |
Sound pressure level |
Cooling |
Nom. |
dBA |
46 |
47 |
50 |
51 |
|
Heating |
Nom. |
dBA |
49 |
51 |
52 |
52 |
Refrigerant |
Type |
|
R-32 |
R-32 |
R-32 |
R-32 |
|
Charge |
kg |
2.95 |
3.75 |
3.75 |
3.75 |
|
Charge |
TCO2Eq |
1.99 |
2.53 |
2.53 |
2.53 |
|
GWP |
|
675 |
675 |
675 |
675 |
Piping connections |
Liquid |
OD |
mm |
9.52 |
9.52 |
9.52 |
9.52 |
|
Gas |
OD |
mm |
15.9 |
15.9 |
15.9 |
15.9 |
|
Piping length |
OU - IU |
Max. |
m |
55 |
85 |
85 |
85 |
|
|
System |
Equivalent |
m |
75 |
100 |
100 |
100 |
|
|
|
Chargeless |
m |
40 |
40 |
40 |
40 |
|
Additional refrigerant charge |
kg/m |
See installation manual |
See installation manual |
See installation manual |
See installation manual |
|
Level difference |
IU - OU |
Max. |
m |
30.0 |
30.0 |
30.0 |
30.0 |
|
|
IU - IU |
Max. |
m |
0.5 |
0.5 |
0.5 |
0.5 |
Standard Accessories |
Tie-wraps |
2 |
2 |
2 |
2 |
|
Installation manual |
1 |
1 |
1 |
1 |
|
Refrigerant label for F-gas regulation |
1 |
1 |
1 |
1 |
|
General safety precautions |
1 |
1 |
1 |
1 |
|
LOT10 Energy Label |
1 |
1 |
1 |
1 |
Power supply |
Phase |
|
3~ |
3~ |
3~ |
3~ |
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
|
Voltage |
V |
380-415 |
380-415 |
380-415 |
380-415 |
Current - 50Hz |
Maximum fuse amps (MFA) |
A |
16 |
16 |
16 |
16 |
Notes |
(1) - According to ENER Lot 21 |
(1) - According to ENER Lot 21 |
(1) - According to ENER Lot 21 |
(1) - According to ENER Lot 21 |
|
(2) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. |
(2) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. |
(2) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. |
(2) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. |
|
(3) - Ssc: Short-circuit power |
(3) - Ssc: Short-circuit power |
(3) - Ssc: Short-circuit power |
(3) - Ssc: Short-circuit power |
|
(4) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current ≤ 16A per phase. |
(4) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current ≤ 16A per phase. |
(4) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current ≤ 16A per phase. |
(4) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current ≤ 16A per phase. |